Description

20DC037A0EYNANANK

 

20DC037A0EYNANANK PowerFlex 700S AC Drive 20D

 

Mechanical 20DC037A0EYNANANK Allen Bradley

Degree of protection (IP) IP20
Shock 10 G peak for 11 ms duration (±1.0 ms)
PWM frequency 4 kHz @ 540V DC
Vibration 0.152 mm (0.006 in.) displacement, 1 G peak, 5.5 Hz

Electrical

Number of analogue outputs 2
Mains voltage 400 V
Integrated breaking resistance No
Max. output voltage 932 V
Internal dynamic brake resistors 68 Ohm
DC bus overvoltage trip 810V DC @ 380/400V
DC nominal bus voltage 540V DC @ 380/400V
Brake IGBT Brake IGBT installed
Internal communication module No communication module
Fuse current rating 70 A @ 540V DC
Input voltage rating 400V AC, 3-phase, 50 Hz
Displacement power factor 0.98 across speed range
Output current, continuous 37 A @ 540V DC
Output current, 1 min 45 A @ 540V DC
Output current, 3 sec 60 A @ 540V DC
Circuit breaker current rating, max 125 A @ 400V AC, 3-phase
Motor circuit protector current rating, max 50 A @ 400V AC, 3-phase
Logic control ride-thru 0.25 seconds, drive not running
Brake resistor No internal brake resistor
Cable 20D-DL2-CL3, 20D-DL2-CR3
Input current rating 40.9 A @ 540V DC
Rated power rating 18.5 kW @ 540V DC, normal duty
Documentation English documentation
Carrier frequency Drive rating: 4 kHz, settings: 2, 4, 6, 8, 10 kHz (6 kHz is for V/Hz operation only)
AC input overvoltage trip 600V AC @ 380/400V (six pulse, 3-phase)
Input power rating 24.3 kVA @ 400V AC, 3-phase
Electronic motor overload protection Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL 508C file E59272
Dual element time delay fuse current rating 45…80 A @ 400V AC, 3-phase
Non-time delay fuse current rating 45…125 A @ 400V AC, 3-phase
Heat sink thermistor Monitored by microprocessor overtemperature trip
Drive to motor power ratio, max The drive to motor rating cannot exceed a 2:1 ratio
Stop modes Multiple programmable stop modes including – Ramp, Coast, and Current Limit
Acceleration/deceleration Independently programmable accel and decel times adjustable from 0 to 6553.5 in 0.1 second increments
Number of digital inputs 6
Number of digital outputs 2
Number of analogue inputs 3
Motor voltage, nom 383V @ 380…400V drive rating, 400V nominal line voltage
Human interface model No HIM (no blank plastic inserted)
Additional configuration Phase II DriveLogix 5730
Max. output frequency 400 Hz
Line voltage, nom 400V @ 380…400V drive rating, 383V nominal motor voltage
Mains frequency 50 Hz
Internal EMC filtering With EMC filter & common mode choke
User available memory base 1.5 MB (compactflash for non-volatile storage also available)
Watt loss 519 W @ 400V AC, 18.5 kW normal duty, 15 kW heavy duty
Feedback option Future use
Drive full power range 383…528V @ 380…400V drive rating, 383V nominal motor voltage
Drive operating range 325…528V @ 380…400V drive rating, 383V nominal motor voltage
Torque regulation Torque regulation – without feedback: ±5%, 600 rad/sec bandwidth
Battery 1769-BA 0.59 g lithium
Enclosure type IP20/NEMA/UL Type 1
Output current rating 37 amps, 18.5 kW normal duty, 15 kW heavy duty, frame 2
Control options Phase II control, expanded cassette
Drive overcurrent trip Software current limit: 105% of motor rated to 200% of drive rated current
Efficiency 97.5% at rated amps, nominal line volts
Speed control Speed regulation – without feedback: 0.1% of base speed across 120:1 speed range, 120:1 operating range, 50 rad/sec bandwidth
Current limit capability Independent motoring and regenerative power limits programmable to 800% of rated output current
Selectable motor control Field oriented control with and without a feedback device and permanent magnet motor control
Serial cable 1761-CBLPM02 to 1761-NET-AIC, 1761-CBLPA00 to 1761-NET-AIC, 1756-CP3 directly to controller,1747-CP3 directly to controller, category 3(2)
Input phases Six-pulse, 3-phase input provides full rating for all drives, single-phase operation provides 50% of rated current
Control method Induction motor and brushless motor: sine coded PWM with programmable carrier frequency, indirect self organized, field-oriented control, current-regulated, ratings apply to all drives, refer to the PowerFlex 700S Phase ll control reference manual, public
Number of phases output 3
Number of phases input 3
Relative symmetric net voltage tolerance 10 %
Input frequency, max 400 Hz
Output frequency range 0 Hz
DC bus undervoltage trip Adjustable
Output voltage range 0 to rated motor voltage
Power ride-thru 15 milliseconds at full load
S-curve time Adjustable 0.5…4.0 seconds
Short circuit trip Phase-to-phase on drive output
Ground fault trip Phase-to-ground on drive output
Control logic noise immunity Showering arc transients upto 1500V peak
Line transients Up to 6000 volts peak per IEEE C62.41-1991
Compact I/O configuration Up to (16) modules (8 modules per bank or 4 max on either side of the power supply)
Intermittent overload 110% overload capability for up to 1 minute, 150% overload capability for up to 3 seconds
Short circuit current, max Using recommended fuse or circuit breaker type: maximum short circuit current rating to match specified fuse/circuit breaker capability ?200000 Amps
Encoder voltage supply 5V DC or 12V DC 320 mA/channel, 5V DC minimum high state voltage state of 0.4V DC, 12V DC minimum high state voltage of 7.0V DC, maximum low state voltage of 0.4V DC

 

Construction

Height, approx 342.5 mm
Depth, approx 200 mm
Width, approx 253.9 mm
Weight, approx Drive: 12.52 kg

 

Shipping & Delivery

International shipping to 240+ countries.

We deliver from 24 Hours directly from our warehouses in England, as well as in the United States of America, handling different Incoterm solutions (DAP -DAT -EXW) and working with companies like DHL, FEDEX, UPS, etc.