Description

1756-EN2TR

 

1756-EN2TR Allen Bradley ControlLogix. 2-port Ethernet module. Dual Copper. Embedded switch. Communications 10/100Mbps. Supports 128 TCP/IP connections.

Technical Specifications 1756EN2TR

Electrical

With optical interface No
Supporting protocol for TCP/IP Yes
Supporting protocol for DeviceNet No
Supporting protocol for other bus systems No
Redundancy Yes
IO link master No
Supporting protocol for DeviceNet Safety No
Supporting protocol for EtherNet/IP Yes
Power dissipation 5.1 W
Thermal dissipation 17.4 BTU/h
Enclosure type rating None (open-style)
Ethernet ports 2 Ethernet RJ45 Category 5
CIP unconnected messages 128 + 128 (backplane + Ethernet)
Current draw 1 A @ 5.1V DC, 3 mA @ 24V DC
Ethernet cable 802.3 compliant shielded or unshielded twisted pair
Wiring category 2 – on Ethernet ports, 3 – on USB ports
Communication rate 10/100 Mbps
Connections supported, max TCP: 128, CIP: 256 (CIP connections can be used for all explicit or all implicit applications. for example, a 1756-ENBT module has a total of 128 CIP connections that can be used for any combination of connections.)
Isolation voltage 30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet(Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC for 60 s
Supporting protocol for LON No
Supporting protocol for ASI No
Supporting protocol for PROFIBUS No
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for KNX No
Supporting protocol for Modbus No
Supporting protocol for Data-Highway No
Supporting protocol for SUCONET No
With potential separation No
Supporting protocol for SERCOS No
Supporting protocol for INTERBUS-Safety No
Radio standard Bluetooth No
Radio standard Wi-Fi 802.11 No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for PROFINET CBA No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
Slot width 1
ATEX temp code T4

1756-EN2TR Environmental

Surrounding air temperature, max 60 °C
Storage temperature -40 °C <Ta <85 °C (-40 °F <Ta <185 °F)
Emissions CISPR 11: Class A
Vibration 2 G @ 10…500 Hz
ESD immunity 6 kV contact discharges, 8 kV air discharges
EFT/B immunity ±3 kV at 5 kHz on Ethernet ports
Relative humidity 5…95% noncondensing
Shock Operating: 30 G, Nonoperating: 30 G
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Surge transient immunity ±2 kV line-earth (CM) on Ethernet ports
Shipping & Delivery

International shipping to 240+ countries.

We deliver from 24 Hours directly from our warehouses in England, as well as in the United States of America, handling different Incoterm solutions (DAP -DAT -EXW) and working with companies like DHL, FEDEX, UPS, etc.